Caustic Soda
Caustic Soda
Pumping considerations
Caustic soda is highly reactive with aluminium, carbon steel and can cause problems with viton and fluorocarbon. Contained handling is highly important as exposure to workforce is highly dangerous. Caustic can crystallize where mechanical seals allow draining of fluid. Expensive double mechanical seals or no mechanical seal systems is usually recommended.
Wilfley’s safe and no leak solution
Wilfley’s dynamic sealing technology in combination with the Drylock static seal with Kalrez elastomer, offers a leak free pumping system without the use of flush water. Pumps run without any external flushing system, providing a reliable operation 24/7 reducing maintenance time and costs. Wilfley’s WCD4 metallurgy provides robust resistance to reactive nature of Caustic Soda. In comparison, high nickel content based metals have porosity issues and are very expensive.